Free Shipping Automatically at $50
Aerotech® AeroSpeed 2.4 - High Performance RC Car for Adults & Kids - Perfect for Racing, Off-Road Adventures & Backyard Fun
Aerotech® AeroSpeed 2.4 - High Performance RC Car for Adults & Kids - Perfect for Racing, Off-Road Adventures & Backyard Fun

Aerotech® AeroSpeed 2.4 - High Performance RC Car for Adults & Kids - Perfect for Racing, Off-Road Adventures & Backyard Fun

$1002.09 $1821.99 -45% OFF

Free shipping on all orders over $50

7-15 days international

17 people viewing this product right now!

30-day free returns

Secure checkout

45917040

Guranteed safe checkout
amex
paypal
discover
mastercard
visa
apple pay

Description

Used to regulate the environment in livestock buildings, the Aerotech AeroSpeed 2.4 maintains your desired temperature in the facility by controlling the operation of ventilation and heating equipment. Two stages of variable speed cooling fans, two stages of constant-speed cooling fans, and two stages of either constant-speed cooling fans or heaters can be connected to the controller. In addition, the last cooling stage can be configured as a mist cooling stage.

Features of the ST 5222:

  • Three Digit Display
      Provides a high level of accuracy, allowing you to specify a temperature to within 1/10 of a degree (in Fahrenheit or Celsius units)
  • Pilot Lights
      Indicate the state of outputs allow you to monitor the operation of the system without having to enter the building
  • Minimum Ventilation Cycle
      When ventilation is not required for cooling, the first stage fans can be operated either continuously or intermittently to reduce the level of humidity and supply oxygen to the room
  • Temperature & Minimum Ventilation Speed Curves
      Can be set to automatically change the temperature set point and minimum ventilation speed over a given period of time in accordance with your requirements by specifying a temperature curve and a minimum ventilation speed curve with up to 6 different points each
  • Choice of 5 Motor Curves
      The variation in motor speed resulting in a change in voltage will depend on the make and capacity of the motor. In order to achieve a high degree of compatibility between controller and motor, you can choose from among 5 different motor curves, to ensure the correct voltage is supplied
  • Full Speed Fan Start-Up
      To overcome the inertia of the ventilation system components and de-ice the fan blades in cold weather conditions, the controller supplies maximum voltage to the variable speed fans for 2 sec immediately following each start-up
  • 4 Independent Temperature Probe Inputs
      Up to 4 temperature probes can be connected to obtain a more accurate reading of the average room temperature and a faster reaction time
  • Overload and Overvoltage Protection
      Fuses are installed at the input and outputs to protect its circuitry in the case of an overload or overvoltage
  • Computer Control
      Can be connected to a computer, making it possible to centralize the management of information and diversify control strategies

Several Models To Choose From. Features of All Models:

  • Fully adjustable temperature and ventilation curves
  • Variable speed outputs have optional timer option
  • Minimum, maximum temperature recordings
  • 12' sensor included
  • 120/240 volt
  • 10 amp maximum fan load

2.4 Technical Specifications:

  • Supply:
      115/230 VAC (-18%-+8%), 60 Hz, L1 same phases as Stage 1, overload and overvoltage protection fuse F11-1A fast blow
      12 VDC for AC back-up supply; can activate stages 3-6 if supplied with DC back-up voltage
  • Stage 1:
      Variable output, 60 Hz, 10A fan (3/4 HP/115 VAC)/(1.5 HP/230 VAC), fuse F1-15A slow blow
  • Stage 2:
      Variable output, 60 Hz, 10A fan (3/4 HP/115 VAC)/(1.5 HP/230 VAC), fuse F8-15A slow blow
  • Stage 3:
      On/Off output, 115/230 VAC, 60 Hz, 30 VDC, 6A Fan, 10A res, fuse F3-15A slow blow
  • Stage 4:
      On/Off output, 115/230 VAC, 60 Hz, 30 VDC, 6A Fan, 10A res, fuse F4-15A slow blow
  • Stage 5:
      On/Off output, 115/230 VAC, 60 Hz, 30 VDC, 6A Fan, 10A res, fuse F5-15A slow blow
  • Stage 6:
      On/Off output, 115/230 VAC, 60 Hz, 30 VDC, 6A Fan, 10A res, heating, fuse F6-15A slow blow
  • Alarm:
      On/Off output, 115/230 VAC, 60 Hz, 30 VDC, 3A, fuse F7-3A slow blow
  • Probes:
      Low voltage (<5V), isolated from the supply. Operating range: -40° F to 120° F. Accuracy: 1.8° F between 41° F and 95° F
  • Enclosure:
      ABS, moisture and dust-tight
  • The room temperature where the controller is located MUST ALWAYS REMAIN between 32° F and 104° F

Factory Settings:

ParameterFactory SettingRange of Values
Temperature Set Point75° F-40° F to 99.9° F
Stage 1Minimum Speed40%10%-100%
Time On15 sec0-900 seconds by
increments of 15 sec
Time Off0 sec
Bandwidth3° F0.5° F - 20° F
Stage 2Minimum Speed40%10%-100%
Starting Temp78.5° FSet point + bandwidth
to set point +
bandwidth +20° F
Bandwidth3° F0.5° - 20° F
Stage 3Starting Temp83.5° FStage 2 starting temp +
0.5° F to Stage 3
starting temp + 20° F
Stage 4Starting Temp85.5° FStage 3 starting temp +
0.5° F to Stage 4
starting temp + 20° F
Stage 5Starting Temp87.5° FStage 4 starting temp +
0.5° F to Stage 4 +
starting temp + 20° F
Stage 6Starting Temp89.5° FStage 5 starting temp +
0.5° F to Stage 5
starting temp + 20° F
MistTime On1 min0-60 min
Time Off0 min
Heater A Starting Temp72.5° FOff temp -0.5° to
off temp -20° F
Heater B Starting Temp70.5° FHeater A starting
temp -0.5° F to Heater A
starting temp -20° F
Heater A/B Off Temp74.5° FSet point -20° F
to set point +10° F
AlarmLow Temp65° F0.5° F - 40° F
from set point
High Temp87° F

These initial parameter settings will not be retained in the controller's memory. Each new setting will replace the preceding one.
If the power supply is cut off, the last parameter settings will be retained in the memory until the power is restored.

ModelQC Part #Mfg Part #Variable Speed OutputsThermal ContactsCooling (only) ContactSensors (max)PC LoopRamping TimerAlarm Contacts
AeroSpeed 1.1ST51101194YesNoYes
AeroSpeed 1.2ST51201214YesNoYes
AeroSpeed 1.3ST5111244YesNoYes
AeroSpeed 1.6ST512412-4YesNoYes
AeroSpeed 2.2ST52202224YesNoYes
AeroSpeed 2.4ST52222225YesYesYes